DGV11 F5 Resilient Seated Gate Valve
Devinsan’s DGV11 F5 Resilient Seated Gate Valve provides dependable shut-off and long-lasting performance for water, wastewater, and fire protection systems. Built from ductile iron, this F5 type gate valve for water system ensures durable operation, excellent corrosion resistance, and tight sealing even under challenging conditions.
Production Standard
Nominal Dimension (DN)
Nominal Pressure (PN)
Operating Temperature
Design
Face to Face
Connection
Coating
Testing
DN 40 – DN 600
PN 6-PN 10-PN 16-PN 25-PN 40
-30° / +200°
EN 1171 – EN 1074
EN 558 Series 15 – DIN 3202 F5
EN 1092-2 ISO7005-2 Flanged
Electrostatic Powder Epoxy
EN 12266-1
Operation Versions
The DGV11 F5 Resilient Seated Gate Valve can be operated with a range of compatible accessories to suit different installation and automation requirements:
1. DVA10 Surface Box & Extension Spindle
2. DVA11 Telescopic Extension Spindle
3. DVA12 Electric Actuators
4. DVA13 Pneumatic Actuators
5. DVA14 Gear Box
6. DVA15 HandWheel
These accessories allow the valve to be adapted for manual, geared, pneumatic, or electric operation, ensuring precise control and reliable performance in both industrial and commercial systems.
Application Areas
The DGV11 F5 Resilient Seated Gate Valve is widely used across diverse industrial and commercial sectors, delivering reliable flow control and long‑lasting performance.
1. Water and Wastewater Systems
2. Chemical Industry
3. Food and Beverage Industry
4. Pharmaceutical Industry
5. Oil and Gas Industry
6. HVAC (Heating, Ventilation, Air Conditioning) Systems
In these applications, this F5 type gate valve ensures precise fluid control, maintains excellent sealing integrity, and supports efficient, safe operation even under demanding conditions.
The DGV11 F5 Resilient Seated Gate Valve is a high-performance isolation valve engineered by Devinsan to deliver reliable flow control and long-lasting operation in modern water, wastewater, and fire protection systems. Built from ductile iron, this valve combines exceptional mechanical strength, corrosion resistance, and structural stability, making it ideal for demanding industrial and municipal applications.
At the heart of the F5 Resilient Seated Gate Valve lies a resilient elastomer-coated wedge that ensures a tight, leak-free seal under all operating conditions. The stainless-steel spindle, operated by a precision-threaded mechanism, provides smooth movement with minimal torque. This design prevents frictional wear, allowing the valve to perform reliably for decades even under high pressure or frequent use. The robust sealing system eliminates leakage, ensuring system safety and efficiency.
The internal geometry of the Ductile Iron Gate Valve F5 promotes an unobstructed, laminar flow, minimizing head loss and turbulence across the line. This efficient design contributes to energy savings and consistent hydraulic performance, which is essential in water distribution networks, pumping stations, and treatment facilities. Compact F5 face-to-face dimensions simplify installation and integration, even in tight spaces or retrofit projects.
Every F5 Type Gate Valve for Water System is coated internally and externally with electrostatic powder epoxy to provide lasting protection against corrosion, abrasion, and soil moisture. This high-quality coating meets potable water standards, ensuring safe operation in drinking water systems. The smooth epoxy finish prevents buildup of deposits and supports long-term hygiene and efficiency.
Devinsan manufactures each F5 Resilient Seated Gate Valve under strict international standards including EN 1171, EN 1074, EN 558 Series 15, DIN 3202 F5, EN 1092-2, ISO 7005-2, and EN 12266-1. Every valve undergoes rigorous hydrostatic and pneumatic testing to confirm body and seat tightness, coating quality, and torque accuracy. These tests ensure that every product provides safe, reliable, and maintenance-free service from installation onward.
The ductile iron gate valve F5 is designed for easy servicing and low maintenance. Its bonnet structure allows access to internal parts without removing the valve from the line. The stainless-steel spindle resists corrosion and maintains smooth operation even in aggressive environments. Seals and gaskets are replaceable using standard tools, minimizing downtime and reducing operating costs.
Sustainability and quality define Devinsan’s production philosophy. The F5 type gate valve for water system uses recyclable materials and environmentally safe coatings, aligning with modern sustainability goals. Its long lifespan and minimal maintenance requirements reduce environmental impact while maintaining performance and cost efficiency.
In conclusion, the DGV11 F5 Resilient Seated Gate Valve represents the ideal balance between durability, functionality, and precision. With its ductile iron construction, resilient sealing system, and corrosion-resistant coating, it ensures leak-free and energy-efficient operation in all service conditions. Designed to meet international quality standards, it stands as a dependable solution for engineers and operators seeking reliability, safety, and long-term value in modern infrastructure systems.
1. General Information
The DGV11 F5 Resilient Seated Gate Valve for water system can be installed in both horizontal and vertical pipelines, with the spindle facing upward for optimal performance. Ensure the system is clean and depressurized before installation.
2. Safety Precautions
Installation must be performed by qualified personnel only.
Ensure compliance with all local safety regulations and standards.
Wear appropriate personal protective equipment (PPE).
Confirm that the pipeline is depressurized and drained before installation.
3. Pre-Installation Checklist
Inspect the valve for any visible damage during transport or storage.
Check that the valve type, size, and pressure rating match the system requirements.
Verify that the valve is clean and free from debris.
Confirm that the pipeline ends are properly aligned and free from burrs or sharp edges.
Ensure sufficient space is available for operation and maintenance.
4. Installation Procedure
Positioning: Install the valve in the correct flow direction as indicated by the arrow on the valve body. The valve can be installed in horizontal or vertical pipelines, with the spindle oriented vertically upward for optimal performance.
Pipeline Preparation: Ensure the pipeline is clean and free from dirt, sand, or foreign particles. Use proper gaskets suitable for the medium and operating conditions.
Mounting the Valve: Align the valve with the pipeline flanges. Insert bolts and tighten them crosswise in gradual steps to ensure even compression of the gasket. Do not use excessive force that may damage the valve body or flanges.
Operational Check: Open and close the valve fully to confirm smooth operation. Ensure the valve closes tightly without leakage.
5. Post-Installation
Slowly pressurize the system and check for leaks around the connections.
If leakage is detected, depressurize and re-tighten the bolts.
Record the installation details for documentation.
Proper maintenance extends the service life of the valve and ensures reliable performance. Follow the guidelines below:
1. Routine Operation
Operate the valve (open/close) periodically to prevent seizure and buildup of deposits on the sealing surfaces.
Avoid using the valve for throttling, as it is designed for on/off service.
2. Inspection Schedule
Monthly: Check for external leaks around body joints, stem packing, and flange connections.
Quarterly: Operate the valve fully open and fully closed to verify smooth operation.
Annually: Perform a detailed inspection including seals, stem, and coating condition.
3. Lubrication
If applicable, lubricate the stem nut or gearbox according to manufacturer’s recommendations.
Ensure moving parts remain free of dirt and corrosion.
4. Seal and Gasket Replacement
Replace stem seals, O-rings, and gaskets if leakage or wear is observed.
Always depressurize and drain the pipeline before performing any maintenance work.
Only use original spare parts to guarantee compatibility and reliability.
5. Cleaning
Keep the exterior of the valve clean to prevent corrosion.
In aggressive environments, consider applying additional protective coating or insulation.
6. Storage and Spare Parts
Store spare parts in a dry, clean environment, away from direct sunlight.
Maintain a record of all inspections, repairs, and replacements.
We prioritize quality at every stage of production to deliver durable, safe, and efficient products. Our continuous improvement and strict quality controls keep us at the forefront of the industry.
Our certifications prove our commitment to excellence and compliance with international standards, ensuring the safety and reliability of our products worldwide.
We continuously invest in innovation and quality to expand our certifications and meet evolving industry needs.
Frequently Asked Questions about the DGV11?
What are the main advantages of this valve?
The DGV11 F5 Resilient Seated Gate Valve is designed for reliable and efficient fluid control, offering smooth low-torque operation, excellent corrosion resistance, and tight sealing performance with its EPDM-coated wedge. Its durable, maintenance-free construction minimizes operating costs and delivers long-term dependability even in the most demanding environments.
Fully compliant with the DIN 3202 F5 standard, the DGV11 F5 is specifically engineered to meet European performance and installation requirements, ensuring accurate flow isolation and superior reliability across various water supply, wastewater treatment, and fire protection systems.
Why should I choose this product?
This valve delivers outstanding performance in both sealing and durability, making it a dependable choice for demanding applications. Its high‑quality epoxy coating protects against corrosion and environmental factors, ensuring reliable operation over time. Designed for easy installation, it can be mounted in both vertical and horizontal positions, offering flexibility during system design. With a wide range of diameter options, it meets the needs of various infrastructure projects, from municipal water networks to industrial facilities.
How is the installation process carried out?
The valve features a robust flanged connection for secure pipeline integration. Before installation, the pipeline interior should be thoroughly cleaned and flange faces precisely aligned to ensure proper sealing. Once the sealing gaskets are positioned, bolts must be tightened evenly with consistent torque to prevent leakage. Designed for versatility, it can be installed in either vertical or horizontal orientations, making it suitable for a wide range of system layouts.
Which standards does this valve comply with?
This model is manufactured in accordance with the DIN 3202 F5 face‑to‑face dimension standard and is designed to meet international quality requirements. Its EPDM‑coated wedge ensures high sealing performance, while the body material and protective coating meet European market expectations for corrosion resistance and durability. As a result, it can be confidently used in both municipal infrastructure projects and industrial facilities.
Can this valve be installed in both vertical and horizontal pipelines?
Yes. The DGV11 F5 is designed for flexible installation and can be mounted in either vertical or horizontal pipeline configurations without affecting performance. Its flanged connection ensures secure integration, while proper alignment and even bolt tightening during installation guarantee optimal sealing. This versatility makes it suitable for a wide range of system layouts in municipal, industrial, and fire protection networks.
Contact Devinsan
Reach out to our team for inquiries, quotes, and technical assistance